Replacement / Renovation
86 VELUX
6
Replacement of roof window
A. REPLACING LINING
Install the roof window following standard procedure and with a
standard flashing.
VELUX installation products BDX, BFX and BBX should be used if
possible.
Note! When using VELUX linings while maintaining the old window
opening, the lining must be specially adjusted (see page 88).
B. KEEPING LINING BUT REDUCING DEPTH
If the window to be replaced is from before October 1998, the new
window will be installed deeper in the roof than the old window.
This means that the lining must be reduced by 27 mm on all sides.
Position frame in the lining and secure with installation brackets.
Fit standard flashing following standard procedure. The lining fits
at the sides but it is necessary to fit facings (a) at top and bottom.
VELUX installation products BDX, BFX should be used if possible.
The frame insulation collar from installation set BDX may have to
be adjusted at the top or bottom.
a